  • Cause of the explosion when the power distribution box was switched on

    Cause of the explosion when the power distribution box was switched on

    A transformer explosion is caused by an internal short-circuit in the transformer. During short-circuit, oil temperature reaches 1200 degrees Celsius, and it gets vapored and evolves into explosive gas. These failures often cause loud. Electrical transformers are very powerful electrical devices and they take megawatts of electrical power and either step up or step down the voltage in order to make it safe for the electrical load attached to the transformer. During this conversion, a lot of stress is applied on the parts of the. Saw a squirrel touch the wrong part of a power line once, an arc and flame the size of a car exploded in the sky and the squirrel fell on the ground and instantly caught the brush around it on fire. It is one of the electrical power grid's most dangerous and disruptive events. Therefore, we need to ensure the reliable operation of the power transformer.

    [PDF Version]
  • Cause of Battery Explosion in Communication Equipment Room

    Cause of Battery Explosion in Communication Equipment Room

    Through disassembly and observation of the battery and iron frame of battery cabinet in the area of fire origin, we obtained the key residual traces and used the physical and chemical analysis methods such as macroscopic/microscopic morphology, EDS, X-ray and metallographic, it was. Through disassembly and observation of the battery and iron frame of battery cabinet in the area of fire origin, we obtained the key residual traces and used the physical and chemical analysis methods such as macroscopic/microscopic morphology, EDS, X-ray and metallographic, it was. Lead-acid battery is a type of secondary battery which uses a positive electrode of brown lead oxide (sometimes called lead peroxide), a negative electrode of metallic lead and an electrolyte of sulfuric acid (in either liquid or gel form). The overall cell reaction of a typical lead-acid cell is:. This paper carried out the fire failure analysis of valve-regulated lead-acid battery in communication equipment room. It is a very good example of what happens if you lose ventilation in a battery charging room. Several battery room explosion incidents support this fact.

    [PDF Version]
  • How many days can argon gas be used in a spectrometer

    How many days can argon gas be used in a spectrometer

    No, argon gas does not go bad because it is an inert noble gas that remains chemically stable indefinitely. We plan to collect the samples to be measured and thus conduct measurements not more than 1 day per week or several days in a row for the whole month. 7L/min for a few hours or 1-2 days beforehand. It would be. The optical chamber of an argon-filled spectrometer is filled with high-purity argon gas, while the surrounding air is exhausted. The ICP-OES instrument consumes argon at a rate of about 20 L/minute; one full compressed argon cylinder will provide about 6-8 hours of running time. Liquid argon is best suited to high and regular usage, as the unit c st is less. £100 per cylinder, so that's £12.

    [PDF Version]